Waters Alliance 2695
- Brand: Waters
- Product Code: Waters Alliance 2695
- Availability: In Stock
Data Sheet: Waters 2695 Data Sheet.pdf
Refurbished Waters 2695 Alliance HPLC complete with Waters 2487 dual absorbance detector (p/n WAT081110), Waters TC2 temperature controle module (p/n 186002441), Waters column heater module (p/n CHM) and Masslynx 4.1 PC workstation.
OPTIONAL: Waters 996 Photodiode array detector(p/n WAT057002), Waters 2996 PDA, Waters 474 Fluorescence Detector (p/n 047400) and Waters column heater (available part numbers: 186001863, 186001791 & WAT270852), Waters Empower 2 PC workstation, Waters Syringe Module (M/Code SM4), Waters Sample heater/ cooler (Available: M/Code SHC, 289000560 & WAT270852), Waters Bus Sat/In module (p/n WAT073640) and Packard 150TR Flow Scintillation Counter. Multiple configurations available.
The Waters Alliance 2695 Separations Module is a high performance liquid chromatographic system with a quaternary, low-pressure mixing pump and inline vacuum degassing. Flow rates from 50 uL/min to 5 mL/min can be generated for use with 2.1 mm ID columns and larger. The autosampler has a maximum capacity of 120 vials (12x32, 2-mL) with programmable temperature control from 4 to 40°C. A heated column compartment provides temperatures from 5 degrees above ambient to 65°C. The detector is a photodiode array (model 2996) with a wavelength range of 190-800 nm and sensitivity settings from 0.0001-2.0000 absorbance units.
Please contact us for complete refurbished and used Waters 2695 HPLC system, warranty and service contract details. (available part numbers: WAT270886 & WAT270008)
OPTIONAL: Waters 996 Photodiode array detector(p/n WAT057002), Waters 2996 PDA, Waters 474 Fluorescence Detector (p/n 047400) and Waters column heater (available part numbers: 186001863, 186001791 & WAT270852), Waters Empower 2 PC workstation, Waters Syringe Module (M/Code SM4), Waters Sample heater/ cooler (Available: M/Code SHC, 289000560 & WAT270852), Waters Bus Sat/In module (p/n WAT073640) and Packard 150TR Flow Scintillation Counter. Multiple configurations available.
The Waters Alliance 2695 Separations Module is a high performance liquid chromatographic system with a quaternary, low-pressure mixing pump and inline vacuum degassing. Flow rates from 50 uL/min to 5 mL/min can be generated for use with 2.1 mm ID columns and larger. The autosampler has a maximum capacity of 120 vials (12x32, 2-mL) with programmable temperature control from 4 to 40°C. A heated column compartment provides temperatures from 5 degrees above ambient to 65°C. The detector is a photodiode array (model 2996) with a wavelength range of 190-800 nm and sensitivity settings from 0.0001-2.0000 absorbance units.
Please contact us for complete refurbished and used Waters 2695 HPLC system, warranty and service contract details. (available part numbers: WAT270886 & WAT270008)